Homogeneous Anti-static PVC/Vinyl Sheet Flooring

Homogeneous Anti-static PVC/Vinyl Sheet Flooring
High performance flexible homogeneous multifunctional floor
UV strengthened, special maintenance treatment, easy maintenance
Strengthened structure to improve wear resistance
Anti-bacteria and mould proof
Antistatic
Get A Quote

Share:

PRODUCT DESCRIPTION

Compact sheet, without foam backing
Dimension: 2.0/3.0mm(thickness)*1.83/2.0m(width)*20m(length)


Characteristic

High performance flexible homogeneous multifunctional floor
UV strengthened, special maintenance treatment, easy maintenance
Strengthened structure to improve wear resistance
Anti-bacteria and mould proof
Antistatic


Application

imgi_7_1

Characteristic

High performance flexible homogeneous multifunctional floor

UV strengthened, special maintenance treatment, easy maintenance

Strengthened structure to improve wear resistance

Anti-bacteria and mould proof

Antistatic

imgi_8_2

Specification

TECHNICAL DATA
Total thicknessEN428
2.0/3.0mm
SizeEN4261.83/2.0mx20m
WeightEN4302900/4350g/m2
Electric propertiesSJ/T11236-2001/EN1081Static Dissipative 1.0x106-10x109Ω


Conductive 1.0x104-10x106Ω
Decay timeSJ/T10694-2006(IVI<100V)EQUAL0.3S
Charge voltageSJ/T10694-2006(IVI<100V)EQUAL70
Fire ratingDIN4120B1
Combustion propertiesSJ/T11236-2001(<10S,FV-0)EQUAL0.35S I FV-0
Smoke densityASTME-662<450
Amount of anti-wearSJ/T11236-2001(≤0.020g/cm2)EQUAL0.014
Ati-bacterialDIN ENISO 846-A/CNo bacteria
Wheel pressureEN425No influence
Toxic testingGB18586-2001Suitable
Smoking toxicityGB8024-2006ZA3
Residual stabilityEN433/SJ/T11236-2001<0.1mm/≤0.15mm
Dimensional stabilityEN434≤0.35%
Color fastnessENISO 105-B02degree 6
Resistance to chemicalsDIN423、FN ISO 26987good
Impact sound absorptionVLI、ISO104、ISO717Approx2dB
Slip ResistanceDIN51130/EN13893R9/DS
Thermal ConductivityEN126670.03w/(M.K)
Clean RoomsASTM F51/68Class A, non-shedding


Suitable for use in flowing classes of


clean room: ISO 1466-11999 Class 4

Application

imgi_9_3

Color reference

imgi_10_4

imgi_11_5


FAQ

Where and why would you use a raised floor?

In a gymnasium, they would want a raised floor to increase the bounce for basketball and vollyball games.In a dance hall a raised floor makes the dancing more lively and the dancers don't tire as easily.In housing the entire house is raised off the ground, on a foundation, in order to keep moisture out, and account for settling of the ground. I asked a home builder whyCalifornia(and increasingly other states)require a concrete slab to be raised off the ground, and he told me it was to keep drafts from coming into the house, and provide the strength necessary to hold up the walls and roof.

Access floor systems offer

Maximum flexibility; maintenance, installation and conversion projects can be executed quickly,        

Floor can be walked on immediately,

Pre-manufactured components parts for dry assembly,

Easy access to all areas of the communication and in-house technique. Non-destructive, without noise, dust and interference of the workflow,

Optimum amount of spare room for future modifications,

Optimum space for large dimensioned air conditioning units, extinguishing systems, and electrical distributors.

The important criteria for choosing an access floor system are the: load-bearing capacity, fire protection, electrostatic behavior and sound absorption.

Load-Bearing capacity

The expected point load determines the requirements for the load-bearing capacity. The nominal point load of a panel is the decisive value for the valuation of the load-bearing capacity.

Electrostatics

Electrostatics loads are generated through friction. Those are not only unpleasant for people but can also affect the function of many electronic devices. The right choice of floor covering in connection with the access floor system provides for the discharge of the loads over the grounded access floor construction.

What types of Floor Panels are available?

Hollow steel, Cementitious filled steel, Concrete filled steel and wood-core (particle board), Calcium sulphate, aluminum systems are available.

What type of system should I use in a Computer Room?

That would depend on the loading being imposed on the floor and the amount of deflection at the design load your project may require. The Industry standard has always been to specify a concentrated load rating at a maximum deflection of .080". However, for the greatest performance a concrete filled steel system in a rigid grid understructure should be specified. This offers optimum loading at .100" deflection with excellent Rolling and Impact loads. Today most users have switched to the concrete filled steel panel due to its increased performance. See Performance Charts.

What finishes are available for use in a Computer Room?

HPL (high pressure laminate) is the standard used in most computer rooms. Some projects require a conductive vinyl or conductive HPL.

What product should be used in a general office application needing a raised floor for Wire Management?

For an office application an Encased calcium sulphate raised floor with magnetic carpet is best.It’s also a leading product ofXL.

What type of system is best used in a Clean Room application?

An all aluminum system is best used in a clean room application. Grates or perforated aluminum panels are used due to the requirement for Laminar Air Floors.

What is the lowest height I can install for access flooring?

35mm is the lowest finished floor height. However, since most concrete slabs aren't perfectly level, a minimum of 50mm is recommended.

Are Computer Floors only used in certain types of projects?

Originally they were only installed in computer rooms. However, in the past 15 years they have evolved into the general office area and are now being designed into a project throughout the facility. Office buildings, schools, hospitals, Internet facilities and libraries are a few of the applications utilizing access flooring.