Understructure System

Understructure System
The Bolted Stringer Understructure System
ATFLOR’s Bolted Stringer System is designed for computer rooms, data centers, industrial applications and heavy rolling load areas.
Brand:ATFLOR
Get A Quote

Share:

PRODUCT DESCRIPTION

The Bolted Stringer Understructure System

ATFLOR’s Bolted Stringer System is designed for computer rooms, data centers, industrial applications and heavy rolling load areas.


For Steel CementitiousInfill

Bolted Stringer System for Steel CementitiousInfill Raised Access Floor (Finished Type)


Key Performance Characteristics

  · Non-rust, anti-corrosion, stability, durable, high bearing capacity

  · Coating: electro-zinc, hot-dip galvanized zinc, epoxy powder, nickel chrome

  · Panels could be fast remove and replace

  · Stringers provide lateral resistance to heavy rolling loads and seismic loading

  · Seismic force-resistant pedestal are available the limit or eliminate the need for special bracing

  · The heights up to 2000mm

imgi_16_55-


Compatible Access Floor Panels

Cementitious Infill Raised Access Floor (Finished Type)

imgi_15_22-


For Woodcore or Calcium Sulphate

Bolted Stringer System for Woodcore / Calcium Sulphate Raised Access Floor (Finished Type)

Key Performance Characteristics

  · Non-rust, anti-corrosion, stability, durable, high bearing capacity

  · Coating: electro-zinc, hot-dip galvanized zinc, epoxy powder, nickel chrome

  · Panels could be fast remove and replace

  · Stringers provide lateral resistance to heavy rolling loads and seismic loading

  · Seismic force-resistant pedestal are available the limit or eliminate the need for special bracing

  · The heights up to 2000mm

imgi_13_11-


Compatible Access Floor Panels

Woodcore / Calcium Sulphate Raised Access Floor (Finished Type)

imgi_16_22

imgi_17_22


For Aluminum

Bolted Stringer System for Aluminum Raised Access Floor (Finished Type)

Option 1- Fully Aluminum Alloy Understructure

Key Performance Characteristics

  · Non-rust, anti-corrosion, stability, durable, high bearing capacity.

  · Coating:epoxy powder, nickel chrome.

  · Panels could be fast remove and replace.

  · Stringers provide lateral resistance to heavy rolling loads and seismic loading.

  · Seismic force-resistant pedestal are available the limit or eliminate the need for special bracing.

  · The heights up to 2000mm.

imgi_10_2-800-800

Option 2- Fully Galvanized Steel Understructure

Key Performance Characteristics

  · Non-rust, anti-corrosion, stability, durable, high bearing capacity.

  · Coating:electro-zinc, hot-dip galvanized zinc, epoxy powder, nickel chrome.

  · Panels could be fast remove and replace.

  · Stringers provide lateral resistance to heavy rolling loads and seismic loading.

  · Seismic force-resistant pedestal are available the limit or eliminate the need for   special bracing.

  · The heights up to 2000mm.

imgi_11_3-800-800

Compatible Access Floor Panels

Aluminum Raised Access Floor (Finished Type)

imgi_12_22


FAQ

Where and why would you use a raised floor?

In a gymnasium, they would want a raised floor to increase the bounce for basketball and vollyball games.In a dance hall a raised floor makes the dancing more lively and the dancers don't tire as easily.In housing the entire house is raised off the ground, on a foundation, in order to keep moisture out, and account for settling of the ground. I asked a home builder whyCalifornia(and increasingly other states)require a concrete slab to be raised off the ground, and he told me it was to keep drafts from coming into the house, and provide the strength necessary to hold up the walls and roof.

Access floor systems offer

Maximum flexibility; maintenance, installation and conversion projects can be executed quickly,        

Floor can be walked on immediately,

Pre-manufactured components parts for dry assembly,

Easy access to all areas of the communication and in-house technique. Non-destructive, without noise, dust and interference of the workflow,

Optimum amount of spare room for future modifications,

Optimum space for large dimensioned air conditioning units, extinguishing systems, and electrical distributors.

The important criteria for choosing an access floor system are the: load-bearing capacity, fire protection, electrostatic behavior and sound absorption.

Load-Bearing capacity

The expected point load determines the requirements for the load-bearing capacity. The nominal point load of a panel is the decisive value for the valuation of the load-bearing capacity.

Electrostatics

Electrostatics loads are generated through friction. Those are not only unpleasant for people but can also affect the function of many electronic devices. The right choice of floor covering in connection with the access floor system provides for the discharge of the loads over the grounded access floor construction.

What types of Floor Panels are available?

Hollow steel, Cementitious filled steel, Concrete filled steel and wood-core (particle board), Calcium sulphate, aluminum systems are available.

What type of system should I use in a Computer Room?

That would depend on the loading being imposed on the floor and the amount of deflection at the design load your project may require. The Industry standard has always been to specify a concentrated load rating at a maximum deflection of .080". However, for the greatest performance a concrete filled steel system in a rigid grid understructure should be specified. This offers optimum loading at .100" deflection with excellent Rolling and Impact loads. Today most users have switched to the concrete filled steel panel due to its increased performance. See Performance Charts.

What finishes are available for use in a Computer Room?

HPL (high pressure laminate) is the standard used in most computer rooms. Some projects require a conductive vinyl or conductive HPL.

What product should be used in a general office application needing a raised floor for Wire Management?

For an office application an Encased calcium sulphate raised floor with magnetic carpet is best.It’s also a leading product ofXL.

What type of system is best used in a Clean Room application?

An all aluminum system is best used in a clean room application. Grates or perforated aluminum panels are used due to the requirement for Laminar Air Floors.

What is the lowest height I can install for access flooring?

35mm is the lowest finished floor height. However, since most concrete slabs aren't perfectly level, a minimum of 50mm is recommended.

Are Computer Floors only used in certain types of projects?

Originally they were only installed in computer rooms. However, in the past 15 years they have evolved into the general office area and are now being designed into a project throughout the facility. Office buildings, schools, hospitals, Internet facilities and libraries are a few of the applications utilizing access flooring.